    HAI Temp sensors sensors, Im confused

    In my case I want to install a Temp sensor on each bedroom so that I could control the dampers and was considering the humidity sensors for the bathroom to set a rule to start the exhaust vent when certain humidity level is reached in the bathroom "getting shower". What are the right sensors...
  2. M

    Lets talk Dampers!

    Thanks for the reply, gives me some ideas, but still confused whether I need HVAC Controller or if the HAI system performs that function. Also how it would be installed on the omnipro. Thanks
  3. M

    Lets talk Dampers!

    What is the best way to tackle this? I have a friend, professional AC guy that will do the connections for me and rework my AC ducks, but I am not sure how the dampers are integrated. Do they get wired directly to the panel? What type dampers should I get?
  4. M

    HAI Temp sensors sensors, Im confused

    I been looking diagrams of the omnistat2 and it shows that the remote sensor "such as the ones I bought" 23A00-1 are wired directly to the omnistat2. Can this sensors be wired to the Omnipro II? If they are wired to the omnipro could I control the dampers based on the temp reading etc from...
  5. M

    Omnistat2 Type of wire?

    Great, My run is about the same distance.
  6. M

    Omnistat2 Type of wire?

    Can I use a cat6 cable to wire the omnistat to the Hai Panel? I have two free cables in the location where i want to install the thermostat, but I can run a 4 cable 18 or 22 gauge if need be, the only reaon I am hesitating is because I already sealed and patched the whole on this location.
  7. M

    Mrspeed's Home Automation Project

    What a task, finished re-wiring the house. Removed the cat6 stranded and replaced with cat6 solid core. Installed the patch panel, will post some pictures in the next day or two after I reconnect the cables to patch panel. Things are looking good! I was able to watch some movies on two of my...
  8. M

    Mrspeed's Home Automation Project

    Thanks for the advice and compliment, I used that box because I needed at least three gangs for the surround sound plus all the other cables. I got my new cable today. SO I will probably be pulling out stuff today and tomorrow and replacing it. Hoping to start using my rack next week!!! I...
  9. M

    Mrspeed's Home Automation Project

    Picture of where my media devices will be mounted. It is not the ideal rack, but unfortunately due to the limited space in the closet and the fact that there is still a sink in it, I had to improvise. I would have liked to install a nice rack that mounts on the wall such as this one...
  10. M

    Mrspeed's Home Automation Project

    Things are moving along, I made a big mistake with my cat 6 cable. I ran stranded instead of solid, I should be getting the solid today or tomorrow and replace the cat6 that I ran. Included are some pics of my progress, please excuse the mess as we are still under construction :o Also this is...
  11. M

    How turn off green light The Omni Console?

    Man this is a little disappointing, on my old system if a zone was open the green light would be off and it would not go on until everything was closed in the house. I kind of liked that.
  12. M

    How turn off green light The Omni Console?

    Is there a way to have the green light turn off, when the zones are not ready? I am visual guy and if I see at a distance that the light is not on, then I know something is open. Also while we are on the subject, I have a panel that is by a glass door. Is there a way to disable the lights on...
  13. M

    Oh, OH, did I mess up?

    Thank you all for the replies and suggestions. As painful as it is, I ended up buying the solid cable. I think down the road road would have been more frustrating if I had problems with the connectors. So while I am in a wiring mood, I decided to do it right the first time. Lesson learned...
  14. M

    Oh, OH, did I mess up?

    According to what I am reading, solid is the right way to terminate cables in the patch panel. Stranded is too flimsy for termination, I am so mad at myself for not researching this prior to making the purchase, this is an $800 dollar mistake on my part ;)
  15. M

    Oh, OH, did I mess up?

    Crap the more I read, the more I realize I made a costly mistake ;) I guess back to monoprice to get the solid cables :(
  16. M

    Oh, OH, did I mess up?

    While reading about diff cat 6 cables I realize that I just got done wiring my house with this cable from monoprice Cat 6 UTP Stranded, In-Wall Rated (CM), 400MHz 24AWG 1000FT Bulk Cable - Black. For what I been reading maybe I should have used solid cable. Will this be a problem, will I need...
  17. M

    Optex 360, motion sensor. how do I wire?

    That is convenient location to place the resistor, thanks for letting me know!
  18. M

    is there a way to test alarm zones?

    Thanks for the great ideas, I am going to work at it immediately after typing this. Fortunately there are no IR sensors on my set up, I will be installing those after I sort the mess! Thanks again!
  19. M

    is there a way to test alarm zones?

    I started to work on my HAI alarm, prior to HAI I had a Ademco 21ip; the way the wire was set up, it used 7 zones on the pannel. I imagine that each contact in my house has an individual cable and they simply spliced two or three contacts into one zone to make it for example master bedroom. Am...
  20. M

    Optex 360, motion sensor. how do I wire?

    To insure I understood you, I attached an image showing the cables the way I think you told me. Is this correct? Also although my cables are marked from my previous alarm installation, and I know which goes to the resistor; I would like to know out of curiosity, of the two cables does it...