Search results

  1. hucker

    4 way switch with UPB switches

    I also did not use any slave switches. My upstairs hall has 4 switches to control a single load. One of the switches actually controls an exterior light (that I added after the house was done). For me when doing the house there were 3 or four locations where I could have used USR's. I chose...
  2. hucker

    Screw Terminals vs RJ45 Jacks

    I use both. Mostly the RJ45 but have uses for both.
  3. hucker

    Do you have a Fry's in your area? If so, please read.

    I've checked the Renton Washington store lately and not found any UPB product. In August I bought 5 appliance modules for 25 bucks...
  4. hucker

    UPB phase coupler poll

    My phase coupler came with me UPB evaluation kit so I installed it even though my initial testing indicated I didn't need it. Two years later I think that anything that improves reliability in *any* way is worth it so were I to do another project I'd just add it in and forget about it.
  5. hucker

    Top 10 Features I Would Like To See In A Lighting Protocol

    Back to the protocol question, these are sort of aimed at UPB and I suppose is expanded a bit to look at a system level than just the communication layer. 1) It would be nice to be able to control the LED via the protocol rather than the device configuration. 2) Tapping multiple...
  6. hucker

    Top 10 Features I Would Like To See In A Lighting Protocol

    You guys sure about 11W at the switch? That is a lot of heat, the switches would be quite warm. My UPB switches consume very little -- it is hard to measure on a kill-a-watt meter even if the switch LED is on.
  7. hucker

    UPB weak signal

    My point on same/other was that 40 of my switches are on other and 6 are on same. Given the choice I would move the PIM to the other phase.
  8. hucker

    UPB weak signal

    I suppose that I should add. I have never had a switch not activate the load even at these very low signal levels. That is super important.
  9. hucker

    UPB weak signal

    New years is over and I'm the only one still up... I've been seeing some UPB strangeness lately and thought that I'd run some tests based on what I've learned in this thread. My house is 3200sqft and 2 of the UPB devices are located in a shed 100 ft away (this distance did not appear to...
  10. hucker

    What is the soccp on IR codes

    My TV has only one composite input and that is hooked up to the VCR. The TV has 7 inputs but only one is a composite input.
  11. hucker

    What is the soccp on IR codes

    Thanks sic! Had no idea that cable existed, that is exactly what I was looking for but I just didn't know it! That cleans things up a lot.
  12. hucker

    What is the soccp on IR codes

    We are one of the families with no TV... at least only a TV for videos. Well for xmas we (I) broke down and got a Wii so now I'm trying to get it all easy to run with our Harmony 880 remote. Everything would work great IF I could select the output from our VCR. Problem is the only IR code is...
  13. hucker

    commercial release of iphone/itouch and blackberry apps

    I have an axis 2400 and tested it with twilo's software using a blackberry curve worked great. I could checkup on our 'chicken cam' on the blackberry. The kids loved keeping track of the chickens that just hatched... ahh technology...
  14. hucker

    Help UPB WAF Emergency

    LightenUP: That is how I would describe it. The lights go off by dimming and sometimes come back sometimes not. (My kids actually have a blast turning them back on for Mom...) I checked out the log and it is hard to tell what is going on since the kids were banging on things while the...
  15. hucker

    Ideas for uses of current detectors

    I'm currently using a 22/4 for monitoring my furnace. It works great.
  16. hucker

    Help UPB WAF Emergency

    Not sure how far away to look. The houses here are on 1.5 acre lots so I don't have that many neighbors. There are lights around but notthing crazy. I don't see any motorized things or things with fans but I'll check again. It started at 5PM yesterday and went to about 7PM. I didn't see...
  17. hucker

    Help UPB WAF Emergency

    I don't think that is it. I watched in the logger and I see the same switch being turned on a bunch of times then off a bunch, randomly. I thought it might be some dimmable flourescents I put in a while ago when I isolated them. Turning them off seemed to fix the problem. Then I turned them...
  18. hucker

    Help UPB WAF Emergency

    I just got home and many of the lights in the house are randomly going on and off, dimming... Very low WAF right now. I've checked noise and I don't see a problem. Any thoughts on this????? This is the first UPB problem that isn't my fault.... Help
  19. hucker

    An Elk system on a budget?

    To keep your budget in check keep your eyes open on ebay and here. I bought all of my alarm/fire alarm stuff right here and on ebay. I'd estimate at 40% of retail maybe less. As I recall the little stuff added up, mag sensors, wire, EOL relays, tools... I am using a CADDX system NE8. It is...
  20. hucker

    UPB PIM connection occasionally fails

    When I started out with UPB a couple years ago I had problems using USB->RS232 adaptors. It would take 4 or 5 connection attempts before UPStart connect. I now have a real RS232 on my HA machine and haven't had a connect problem in years.
Back