Search results

  1. T

    Any expérience with this web / 1-wire weather Device ?

    Not correct : it accepts up to 6 ds1820 temp sensors or their 1-wire based humidity sensor I read all the manual :-) They don't support (yet) HB sensors but I have asked them feedback about their roadmap I will keep you in the loop
  2. T

    Any expérience with this web / 1-wire weather Device ?

    Hello I find this device x320m : http://www.controlbyweb.com/x320m/ Very very promising device for weather stations and dashboarding I Presume this is compatible with HB thermo and humidity sensors Any experience with this ? thomas
  3. T

    Beta test a free android app for WebControl

    Soon the same for iOS ? If you need beta tester I can send you my udid
  4. T

    HB dual counter: battery too old ?

    Tx However I measure a correct 3v on the pcb below the battery Strange !
  5. T

    Terminal boards for WebControl

    Hello Maybe for Revision 2.0, but here are some ideas for your expansion board: -Add opto-coupler for all 8 logical inputs -Add small SSR as output protection: PVT312 -one ground 0V connection point is maybe too few for 8 inputs ? Thank you
  6. T

    HB dual counter: battery too old ?

    Any idea where I can find such cell with small connected pins ?
  7. T

    HB dual counter: battery too old ?

    The cell is soldered via 2 small pins on the pcb as stated in the manual Strange they are flat. As I did solder myself need to check if this is well done first ... Thank you
  8. T

    HB dual counter: battery too old ?

    Hello I bought some dual counters in 2010. seems now that each time I disconnect from the 1w network, their counters are reset to 0. Battery expired ? How can I be sure ? Easily replacable ? Seems I need to solder. Hope not double face.... why not using a small battery plug to facilitate...
  9. T

    6-channel hub vs. master hub?

    Hello I was wondering if this 6 channels hub has ESD protection ? Or should I interconnect between the hub and each sensors leg some ESD protection ? Can you recommend some schematics, compatible with your RJ45 wiring ? (Data, +5V, GND, +15V power) Thank you
  10. T

    6-channel hub vs. master hub?

    Yes i do connect ps Tonight I will start to re install full new Debian wheezy with last drivers on my sheeva Maybe problem with pl2303 driver (unstable) Also stability issue with digitemp :-(
  11. T

    6-channel hub vs. master hub?

    Hello again I move forward. I tried to install owfs on a sheevaplug computer with Debian Squeeze. Seems to work with my DS9097U and Serial-to-usb adapter. I can read 1wire lan value But when I replace the DS9097U serial interface with the masterhub serial interface, owfs does not work anymore...
  12. T

    Anybody interested in WebControl BRE web GUI source

    Hello Do you think it will be possible to publish Plc HTML source code ? I have release 3.00.07 release Thank you
  13. T

    6-channel hub vs. master hub?

    Hello Eric When I connect the DS9490R USB, I can manage my 1-wire network on my synology DS211. I found owfs compiled for it. I have a 6 ports master hub with serial link. I would like to connect it via RS232-USB adapter to my synology to extend to more networks (star) But I don't know which...
  14. T

    Humidity measure falls to 0 when reaching 100%

    Hello I tried with 4700ohms resistor but measure drops to 0% always Then I increase gradually the resistor but when I get again correct measures, the sensor is still saturating when reacing 100% and drops to 0% again... I think there is a problem in the firmware Thomas
  15. T

    Humidity measure falls to 0 when reaching 100%

    I will try but strange as all Dallas temp sensors are together and some give stable values and others fluctuating value
  16. T

    Humidity measure falls to 0 when reaching 100%

    Thank you. I will add this resistor between sensor output and ground to test. Please note that I have also some strange fluctuations with DS1820 Temperature sensors: the value changes +/1°c every measure. have a look on "T1" https://cosm.com/feeds/80285 I don't have this behaviour on all...
  17. T

    Humidity measure falls to 0 when reaching 100%

    Hello I have a domestic HVAC system in my house. In my basement, I've installed the Honeywell HH4000 sensor in the pipe that takes the wet air from bathroom (+/-15m far away from bathroom) This sensor is connected to webcontrol Humidity entry. I measure, when we take a shower, an increase...
  18. T

    How to count pulse from water flow or energy meter ?

    Hello I wonder how the web control can be used to count pulse going out energy meter ( 1 pulse per w/h) or water flow meter (1 pulse per liter ) I,Owen an 'old'' PLC without pulse function. Is that possible on multiple RTL inputs ? I have many pulse counters needed How is it possible with the...
  19. T

    Alternative humidity sensor ?

    Hello Do you know good Humidity sensor to replace the expensive honeywell 4000 serie , working fine with the WC board ? Thank you Thomas
  20. T

    Use internet online tool to log Webcontrol values

    Very interesting ! Can you share this code to perform the logging ? or is this a commercial product ? works on php + mysql ? RRD ? I have already configured all the hardware (DS Themo probe, relay,...)