    Has anyone been able to download the 3.15 firmware version?

    You can only update firmware with the new boards right?
  2. D

    After firmware upgrade to 3.15, time/date/location issues

    Did you check or un-check the daylight savings box? That would affect the sunrise/set by exactly 1 hour. 
  3. D

    UPB configuration into OminPro

    I installed another new PCS PulseWorks dimmer today. Fired up UpStart and see it was already configured with preset scene links. They were set as scene1-8, but they were there. Programmed the switch with the settings from the HAI matrix, and successly can read status.   I am assuming to use the...
  4. D

    UPB configuration into OminPro

    Thanks Pete. What I needed was the RJ12 6P6C to attach the HAI PIM to the OPII. Just found and attached one and I now have full tracking of status on OPII when load is operated at switch. FINALLY! Now I can confidently add UPB switches and configure my automation using local switch statuses, and...
  5. D

    UPB configuration into OminPro

    Thanks Pete. I have the cable for use with the DB-9 serial connector That is a 4pin/conductor. I need the 6 pin one for the PIM to OPII and will have to make one. I don't think the serial ports on my OPII are RJ45 either. They are smaller like a regular x-10 or phone jack.
  6. D

    UPB configuration into OminPro

    So I am leaning towards the fact I do not have the correct cable to connect my HAI PIM to the OPII. I am not able to locate one online and before I make one, can one of you gentlemen please confirm that it is a 6 conductor cable and is wired straight through. Thanks in advance. 
  7. D

    UPB configuration into OminPro

    Bought a USB to RS-232 adapter. Installed the associated software, hooked up the HAI PIM and UpStart program can not find it. I have the correct com port and have tried different ones as well.  The HAI PIM is plugged in and the LED is orange. Am I doing something wrong, or is the HAI PIM toast...
  8. D

    UPB configuration into OminPro

    I just looked at the PIM and see when I press the switches locally it is flashes green which indicates it is receiving signal. I know it's not as technical as running a diagnostic test, but re-connecting the computer with a DB-9 port will be a PITA. That computer won't run UpStart due to...
  9. D

    UPB configuration into OminPro

    Thanks guys. I will start there. I just moved the HAI PIM to the leg that the switch is on and still not getting signal. I will check the PIM function next. Just have to find a PC with the DB-9 serial port. You guys have been a great help to me and are definitely an asset to this board and the...
  10. D

    UPB configuration into OminPro

    The switches are sending the status links as the Upstart is showing them, so it's not on that end. I added a test block for a UPB link and the OPII did not execute, so it is not getting the signal from the switch.   The OPII did execute a link activation sent from UpStart.   According to UpStart...
  11. D

    UPB configuration into OminPro

    UPB delay is set to 5. If that is what they call status time in PCAccess?
  12. D

    UPB configuration into OminPro

    The OPII will update status of the UPB's in UPB mode when they are operated locally? That is mainly what I am after so I can have a switch tapped locally run a macro. IE; turn the kitchen island light on locally and have the undercounter lights come up to 50%. I know I can link them if they are...
  13. D

    UPB configuration into OminPro

    Yes, I have each block of UPB's in the OPII as HLC with the first unit (49 in the hall/BR block) being the room name. I have only 1 switch in this block so far which is the foyer (50).     So, whereas I am programming the UPB in room 7, should I be using links 37-42 in UpStart as shown in the...
  14. D

    UPB configuration into OminPro

    [sharedmedia=gallery:images:848] [sharedmedia=gallery:images:849] [sharedmedia=gallery:images:850]   I have the scene links as  UPB link 241(off), and 242 (on) as dictated in the HLC on OPII. The units in PCA are configued as HLC. 