Recent content by dtreyes

  1. D

    Elk-M1 Interface for insteon PLM ??

    My PLM is right now controlled by Homeseer and everytime I restart Homeseer, the plugin shows the PLM firmware version on the log
  2. D

    Elk-M1 Interface for insteon PLM ??

    Does this require a newer version of PLM firmware. I bought my PLM a while back and I believe I have version 52 firmware ??? I now that firmware is not upgradeable on PLM.
  3. D

    Water Sensor

    The 2 ends are attached to my ELK digital input and works great. It already saved me once when I had another leak. Another option would be to use 3 water leaf sensor. This is how I am going to do it, wrap around the PVC with sponges and then place the 3 leaf sensor in triangle to make sure it...
  4. D

    Water Sensor

    Attached is a cut-out pic. Wrap around the first layer of copper wire then the paper towel to act as insulator and then the second layer of copper and finally the sponge to trap those water that would flow through the pipe. You can use a piece of cloth instead of paper towel.
  5. D

    Water Sensor

    It is in the far end of my attic, but let me see what I can do.
  6. D

    Water Sensor

    What I did was wrap 2 copper wires around the pvc pipe separated by 2 sheets of "dry" paper towel so they won"t get in contact and finally wrap them around with sponge (2 pieces to completely wrap them around) so water would be absorbed by the sponge, soak the paper towel wet and circuit would...
  7. D

    ElkRP conflicts and disabled rule

    Since I have M1XEP and connect to M1 from diff machines on the network, does that mean I need to sync the database to all those machines that I am using.
  8. D

    ElkRP conflicts and disabled rule

    I just noticed that whenver I disable a rule from ELKRP, I get conflict the next time I connect to the system through ELKRP. Is this by design ??? What is the best practice to temporarily disable elk rules. Thanks
  9. D

    Leaf Wetness Sensor in Stock

    Oh, just to make sure I am clear, no sensor added !!!
  10. D

    Enrolling Wireless Crystal to M1Xrf2G

    Thanks, I knew I am missing something
  11. D

    Enrolling Wireless Crystal to M1Xrf2G

    When I tried to enroll using the keypad, the TXID on the ELKRP remains 0's, although the keypad shows the generated TxID. Am I missing something ???
  12. D

    Leaf Wetness Sensor in Stock

    With M1, I did not have to add anything. When I dip the 2 contacts into the water, M1 changed the state of the digital input.
  13. D

    inexpensive pressure sensors

    Check this out: http://www.trossenrobotics.com/store/p/350...t-14-x-30-.aspx
  14. D

    Enrolling Wireless Crystal to M1Xrf2G

    Can someone please let me know the proper way of enrolling crystall wireless devices to M1g xrf2G. I have been using the method of providing the TxID on the wireless setup screen and they seem to work, but the xrf2G manual said to use the tamper switch. I tried using what the manual said...
  15. D

    Elk M1 & W800RF32 response time.

    I have this same issue which I posted here couple of months ago but did not get anywhere. You are not alone. I wish we can figure out how to improve this response time.