Inside the M1G plastic case. Per the M1 install guide:
Lithium 3V "Clock" battery, Varta #CR2032 located in upper left corner behind cover. Battery has a life expectancy of approx. 10 years. Replace ONLY with exact model available at most electronics and camera retailers. "CAUTION: Lithium...
Thanks for the reply. Elve looks interesting, but the project seems to have gone dead. The last SW update is over a year ago. There's been discussion on open sourcing it, but those seem to have gone fallow as of last summer too.
I think I'll continue to research the ISY or HomeTroller Zee...
I've been running an M1 for a long while and have been happy with it. I have the XEP and XSZLW/VRC0P integration with a couple of 2Gig stats.
I'm looking for an inexpensive add-on that will allow me to do a bit more with rules, including sending emails with dynamic content. My preference...
I've done Elk thermostat integrations in the past using RCS and HAI devices. Hoewever, in looking at RCS, they no longer seem to have hardwired stats and I see no other hardwired stat options for Elk besides the Apirlaire and HAI.
The use case I'm looking to solve is two neighboring...
Sorry for reviving an old thread, but I'm having trouble with my Uplink 2500 and have decided to upgrade to the 4500. I'm going to take the old cable and hack it to work.
It looks like this will be a good connector for the 4500 end and I'd appreciate it if anyone who has one can verify.
...
Happy New Year folks.
A friend asked me about the SimpliSafe system. They're enamored of the wireless sensors, built-in cellular up-link, and email & SMS based alerting.
This looks like a low end consumer system and the negative posts almost all speak to the lack of reliability of the...
Thanks. Neither is working.
For all: This is a system that's been working for over 5 years. It seems to have failed to come back from an extended (>50 hour) power loss.
Hadn't tried that, but just did. After entry of each part of the time (DOW, month, day, year, hours, minutes) the previous entry zeros out. Nothing ends up being set. Wondering if the RTC chip is fried..
Howdy folks. Back from a visit and I'm trying to put things right after the house was without power during the mid-atlantic storms a week ago.
M1 is showing 1/1/2000 12:00:00AM. I tried setting via NTP. Then power cycled the M1. Then tried setting via RP "Set Date/Time from PC". None of...
I changed the RCS to become unit #2 and all is working. So it looks like thermostats have to have globally unique addresses.
Since it was #1, I had to modify existing rules to point to the different number.
Fixed. Didn't change a thing wiring wise.
What I did was to renumber the "network address" of the existing RCS thermostat from 1 to 2.
It looks like the thermostat addresses need to be globally unique. Since they were hanging off of different XSPs, I hadn't thought there would be a conflict...
More info:
The Omnistat is "unit #1", hooked to XSP #1.
The RCS is "unit #1", hooked to XSP #2.
Should I re-address the RCS to start at "network address 2"?
In other words, is the M1 thermostat # in RP the network or unit address of the device regardless of which XSP it is connected to? If...