Recent content by MSTIMMELL

  1. MSTIMMELL

    HAI Omni Pro II Email / Text

    I at least got my Email, text working by using Levitons My Cloud    buried deep in the Catacombs of Knowledge base their is directions by Emie Sieber that worked. Now I will try at my offsite locations.. Does not use SMTP2GO  but rather Levitons Cloud Relay for their newer products.
  2. MSTIMMELL

    HAI Omni Pro II Email / Text

    The Email Text  board just stopped working for multiple sites.  Verizon Phones get their text about 80%  Any Idea's Using SMTP2GO as the relay - It's been working for 5 years at 6 locations..
  3. MSTIMMELL

    HAI Program a status for use with APP

    I found a solution.. I added a X10 unit to my system M1   Then programmed the Garage door Contact  to turn ON if Closed and Off if Open.. Excluded it from All ON/OFF   since this is the first unit it now easy to see if the Door is closed when I'm away from Home on my IPhone Snaplink App..   I...
  4. MSTIMMELL

    HAI Program a status for use with APP

    Leviton Snaplink  System programmed with PC Access IPhone
  5. MSTIMMELL

    HAI Program a status for use with APP

    Question looking for ideas How to program a status that I can see on my Phone APP Garage Door has Sensor so how do I set a status that shows me on the App if I garage door is Open or Closed.. thanks.    
  6. MSTIMMELL

    Sony and Just Add Power

    I've had a problem come up on a system that's been running for 1.5 years..   Running Youtube app on Sony BDP-S6700 through JAP 2G+ system the Audio get garbled (for lack of a better word) I've eliminated everything except the Sony and the JAP Transmitter/Receiver.. (Everything else works...
  7. MSTIMMELL

    Driveway/Sidewalk Heater

    Has anyone ever put in TStat to control Boiler - underground Piping...  With Temperature and Some Type of Snow/Ice Sensor on the Driveway? If so I would be interested to hear your solution and/or Idea's   Thanks, Mark    
  8. MSTIMMELL

    HAI 2 wire heat

    Finally got a hold of System Sensor  the Heat Sensor is 15 to 35 Volts..  Don't know why it reports as OK  on 12 volts..  but I ordered a replacement 5604 and I will be done with it today..  Thanks everyone for your input and support. 
  9. MSTIMMELL

    HAI 2 wire heat

    The  4451 has Blinking status LEDS   So they need some voltage.    It now reports OK and test OK     From now on it's 4 wire Heat for me.  ..  ..    
  10. MSTIMMELL

    HAI 2 wire heat

    I got it to work...  Red  +12volts on the 12V Switched + Terminal   The - or Black wire to the + terminal on the Omni Zone...  Jumper set to SMK... I wish this was somewhere in the HAI litature..  Zone set to FIRE...  have to wait 80 seconds for the unit to reset...      Thanks for the input..
  11. MSTIMMELL

    HAI 2 wire heat

    HAI Omnipro II
  12. MSTIMMELL

    HAI 2 wire heat

    Does a system sensor 4451 2 wire heat detector wire the same as a 2 wire smoke  