    Guys 100% guilty of killing her. Why?!? Who knows why besides him.
  2. Teken

    Is my battery going bad? Corrision?

    People will always take the easy route if available that’s just human nature. As you noted experience whether good or bad mostly changes what people do later on in life. Regardless, my reply was to affirm the importance of doing regular load testing as this is the only way to determine a...
  3. Teken

    Trouble accessing cocoontech.com

    That’s much harder to do on Tapatalk never mind defeats the purpose of the quote button - no?!?
  4. Teken

    Trouble accessing cocoontech.com

    I’ve narrowed down the root cause to this problem. It appears if you quote someone and try to reply this issue is present?!? Removing the quote allows a reply to be submitted. If someone could look into that it would be great because it breaks the flow of a conversation and no one knows who is...
  5. Teken

    Is my battery going bad? Corrision?

    You got be kidding me that absolutely can’t be true unless every one is working on a flat roof?!? Fall arrest protection is mandated by every health and safety organization never mind OSHA. Jacks, no lock?!? It’s a lever that’s existed on every Jack for decades! The creeper that allows a...
  6. Teken

    Is my battery going bad? Corrision?

    Only floss twice a day, don’t need to check tire pressure as it’s displayed on the dash. I do however check the torque on each lug nut after the change over at the 100 KM mark! All loads (energy-power-voltage-current-PF-VA) are monitored at the point of use and branch circuit and any faults are...
  7. Teken

    Is my battery going bad? Corrision?

    You should be load testing the battery every month to insure its fully operational and offers the stated runtime you need. Don’t rely on the alarm panels battery detection to affirm the same. A live system tests is mandatory to validate the BUB offers enough current to provide the 20 hours...
  8. Teken

    Trouble accessing cocoontech.com

    Having posting issues via Tapatalk. This is the message from one of the threads I wanted to reply to.
  9. Teken

    Water Hero - Water Monitoring / Shut off valve system

      The ultrasonic method is tried and true but as you clearly stated they can not provide data for low draw conditions. The method Water Hero is using is proven and there is no magic to it and it measures the movement of the dial. Exactly as you're charged by the water company so the data is...
  10. Teken

    Water Hero - Water Monitoring / Shut off valve system

    The true benefit of this system is not that it can be programmed to turn on-off the main water supply. Its the fact it allows anybody to monitor the water usage with out replacing the actual meter or have some kind of invasive solution in place.   Having the ability to track usage, trends, and...
  11. Teken

    Water Hero - Water Monitoring / Shut off valve system

      Yes . . .   The beauty of this method is that it does not require a person to remove an existing water meter. Does not require a person to hire a plumber or do the job themselves and cut any piping.   Having said this they do in fact offer another model that allows more applications scenarios...
  12. Teken

    Water Hero - Water Monitoring / Shut off valve system

      The link I provided to the vendors site explains which meters are supported.
  13. Teken

    Water Hero - Water Monitoring / Shut off valve system

      As I understand it the flow meter *sensor* monitors the movement of the water meter dial using magnetic displacement sensing. 
  14. Teken

    Water Hero - Water Monitoring / Shut off valve system

    I wanted to update this thread that the Water Hero team has provided some updates and a new web site which offers more insight and comparisons of the products soon to be released to the general public. The direct link to the company is here: http://www.waterheroinc.com/#Home The update link...
  15. Teken

    Water Hero - Water Monitoring / Shut off valve system

    Its too bad some of the members have such odd water requirements and design. I will update this thread once alpha testing begins in the New Year. Again, much thanks to all those who helped push this project forward. Without the support of this site and many others this would still have been a...