Recent content by vining

  1. V

    HAI Email/Text Notifications

    Does the email notification board work? I have one installed and it doesnt seem to do anything. I have the latest FW on both the board and the Omni Pro, Im using the same credentials that are working on my AMX processor and yes I could send the emails through AMX but the notifications board...
  2. V

    HAI serial port ?

    Well I set up a relay today to switch just the TX pin of the serial ports so I can send a serial string to the RA2 master to start and stop the emergency scene and it worked alright.  I already figured in a delay after making the switching relay (basic RIB U1C) but ended up having to installed a...
  3. V

    HAI serial port ?

    That's a possibilty, never had a need to use one before and for my intended use and purpose collisions and data corruption would be extremely unlikely. I think if I were to go this route I'd try the relay idea I mentioned earlier to switch the TX line out of each port just to see if it works...
  4. V

    HAI serial port ?

    I was thinking I could install a relay controlled by an HAI output, use the common to go the Lutron's RX, the NC side to the RA2 config'd port's TX and the NO side the TX of a 2nd serial port config'd as pro link.  Then I could just activate that output to pull in the relay prior to sending my...
  5. V

    HAI serial port ?

    Quick question that unfortunately I can't get from HAI as their answers are usually wrong, useless or they don't respond.   Q.  If a serial port in configured as RA2 should I still be able to send my own formatted string out that port?   The port is working fine for my defined Units and Scenes...