Recent content by cwagner2401

  1. C

    ELK M1G and the ELK-110v5 - how do I get CO/Fire/Burglar to work?

    I found my problem.    Reading a post from Spanky on another thread, I found that on non-burglar zones (Type=0) and when using EOL resistors,  an open loop shows trouble and a shorted loop across the EOL resistor goes into alarm. This is why I didn't get an alarm when the loop went open.   I...
  2. C

    ELK M1G and the ELK-110v5 - how do I get CO/Fire/Burglar to work?

    Thanks.  I read some more and did some experimenting.  I think I can ask a more specific question now... .   I removed the VSD-208 and terminated output 2 with a 2.2K resistor.   The speakers attached to Output 1 are annunciating Fire and Burg alarms (both siren and voice).   However, the CO...
  3. C

    ELK M1G and the ELK-110v5 - how do I get CO/Fire/Burglar to work?

    That's good to hear.   Can you please share how you did it?   Thanks again.    
  4. C

    ELK M1G and the ELK-110v5 - how do I get CO/Fire/Burglar to work?

    Thanks for the fast reply.     I use the Siren Driver because the M1 can't generate an alternating Siren/voice.    
  5. C

    ELK M1G and the ELK-110v5 - how do I get CO/Fire/Burglar to work?

    Hi.   Does anyone have a best practice to share regarding wiring and programming the M1G to use the ELK-110(v5) Voice Driver for separate Fire, Burglar and CO annunciations?   Today, I have a Potter Signal VSD-208 voice siren drive connected to Out2 of my M1.  When the M1 gets a CO alarm, it...
Back