Recent content by DanBarclay

  1. D

    Central Monitoring

    AlarmRelay here as well.  Interface is with ipDataTell equipment.  CDMA-BAT provides both ethernet and cell communication so network backed up by cellular.  Never had a problem with it, easy to set up.  Great support during setup.
  2. D

    Dakota Alert Driveway Sensors?

    The hole is the expensive part.  Once the trench is open, fill it with empty conduit.  Seriously.   If you're building your own place, one you expect to be in a while, over preparation is cheaper than retrofitting later.  YMMV if you plan to sell relatively soon, a new buyer won't see or care...
  3. D

    Elevator and OP II on AT&T Cellular

    For OPII AlarmRelay uses the IPDatatel BAT.  It hooks directly to the phone terminals of the Omni, but only connects/reports alarm events.  It does not dial or connect voice for sending messages outbound or inbound.  While it has worked well for me with regard to alarm connection, there is no...
  4. D

    Controlling UPB switch Status LED with OmniPro?

    Rats.    It sure seemed like a good idea.   I outsmarted myself again.   Thanks, Dan
  5. D

    Controlling UPB switch Status LED with OmniPro?

    Hi Cobra, thanks for the reply.   Sorry I'm not more clear.  I'm familiar with how to get the indictor to be "red when on" or "blue when on" etc.  I'm trying to use the indicator for something other than light on/off.  As an example, use it as an indicator of system arm status or some other...
  6. D

    Controlling UPB switch Status LED with OmniPro?

    This is a standard 600w dimmer, not a key pad if that's what you mean.  Or, are you treating the dimmer as a key pad?   For dimmers I have not seen any option in UpStart for adjusting anything but the switch output (light level) via links.   UpStart as well as the OminPro through PC Access has...
  7. D

    Controlling UPB switch Status LED with OmniPro?

    The ones I'm fooling with now are HAI (35A00-1).  Upstart reports the firmware as v1.08   However, I also have a few PCS switches available but don't have the firmware/version/model info on those available.   I'm probably overdue updating the OmniPro chip so can do that if that is a constraint...
  8. D

    Controlling UPB switch Status LED with OmniPro?

    It occurred to me that I should be able to control the Status LED on the front of a UPB switch using the Omni, similar to the House and Room panel button LEDs.    Setting it to various on/off options using UPstart is straightforward enough, but changing those options (or the LED status itself)...
  9. D

    Trane XL850 Integration

    Thanks!  The thermostat is their XL824 It's set up with a 2 stage condenser unit.     I'll check on communication protocols, but they may not be straightforward.  The manual indicates Z-Wave, but their literature is focused on the wifi/Nexia angle.   I have an OmniStat but would like to leave...
  10. D

    Trane XL850 Integration

    Does Trane publish an API for either wifi access to their tstats, or api access to their online (Nexia)?   Thanks, Dan