In thinking through the issue, in looking at the facts that the ELK would send commands fine but have problems receiving. I checked the sensitivity setting and it was set to high which was causing noise issues with the PIM-E. Setting the Sensitivity on the PIM-E to Low corrected the issue...
I have rules which on a door open turning lights on and they work fine sending out UPB activate links. The problem is that when a wall switch state is changed the ELK does not seem to see it. I'm using the new PIM-E device which ties directly to the ELK 485 network. Since the ELK has no...
So if I understand your comment then UPB Device addresses 1 to 192 are for the ELK panel to send control Links and Addresses 193 to 254 are for receiving link data or sending out link commands. In this application we want to detect any of 3 different light switches (SA US11-40-W) then generate...
I've installed an ELK sysetm in my home and am using UPB devices from Simply Automated and HAI. I'm having a problem with Commands sent from dimmers/switches being recognized in the rules of the ELK M1 System. I've/ set all the devices to report/transmit status but a large number of the...