Recent content by globramma

  1. G

    UPB dimmer and LED lighting

    I understand what you mean. The LEDs run at a very low voltage, so you're saying it doesn't really matter if you shave off X% of 120 volts using a resistor. Even if the bulb only got 50 volts it would (if the driver circuitry accepted 50 volts) work fine because the driver is going to drop that...
  2. G

    UPB dimmer and LED lighting

    Question about the ILR-10K resistor from PulseWorx --   In my setups, which use SAI 11-40 and 2-40 UPB dimmer switches, with 2 or 3 CREE A19-style soft-white LED bulbs per overhead fixture, I have no problems with flicker or with the bulbs shutting off completely. But the dimming bottoms out...
  3. G

    Experiences with UPB (powerline control), & possible other options

      Not sure you understood me correctly. I characterized INSTEON as a kludge because INSTEON's wire-line signalling strongly resembles X10, with X10's well-known flaws -- the "kludge" part coming when INSTEON had a separate RF layer added to it (while keeping the same X10-based wire-line methods)...
  4. G

    Experiences with UPB (powerline control), & possible other options

    If anyone can speak authoritatively on the differences between Gen I and Gen II UPB, and the implementations (or lack thereof) in SA vs. Web Mountain hardware, I'd appreciate it. I'm confused now, & a little concerned that I've already started investing in the less expensive SAI switches.
  5. G

    Experiences with UPB (powerline control), & possible other options

      To clarify -- if I bought SAI UPB switches, I can send them in to Web Mountain for a firmware upgrade?  Is it just a firmware update or do they have to change circuit components or IC's? How much does the upgrade cost?
  6. G

    Experiences with UPB (powerline control), & possible other options

    Thanks @tannebil and @batwater for reporting on your setups and experiences over long periods in some detail. I'm encouraged that I've chosen UPB, and SAI as a vendor, for my power-line control needs. More thoughts follow.     Like X10 before it, I agree that UPB (and many other proprietary...
  7. G

    Experiences with UPB (powerline control), & possible other options

      Well, with due respect it seems like the flakiness could be legitimately in your house wiring, not in the UPB devices. I only mention that to balance the supposition that the problem is UPB itself, or a particular vendor's hardware implementation. So that others who may consider it don't take...
  8. G

    Experiences with UPB (powerline control), & possible other options

        If the problems are reproducible & stable that is encouraging & probably points toward a problem with a specific wire path, i.e. maybe too many branches causing reflections, or a bad / old splice somewhere. Might be worth pulling the affected devices & putting them on a test bench w/ a short...
  9. G

    Experiences with UPB (powerline control), & possible other options

      My understanding is that INSTEON began as a powerline-only protocol, but it was so janky and unreliable they had to "tack on" RF functionality, turning it into a hybrid / frankenstein. From the current INSTEON white paper we can see that on the powerline side INSTEON resembles X10...
  10. G

    Experiences with UPB (powerline control), & possible other options

    @DaAwesomeP, always appreciate having a perspective other than my own. I'm sure results do vary considerably depending on wiring configuration / quality / complexity, and # of UPB devices on the network. FWIW my setup so far consists of just 3 SAI (Simply Automated) 1-circuit dimmer switches...
  11. G

    Experiences with UPB (powerline control), & possible other options

    UPB (universal powerline bus)  seems like a very robust & therefore useful protocol. I haven't used HAI/Omnilink but my understanding is that it is kind of a kludge by comparison. UPB devices are $$$ but having them work reliably is worth it. PLC (power line control) also seems very robust but...