I hooked up my w800 to realterm (like hyperterminal but shows hex). The demo software bytes are clearly converted. My data is very similar to yours. For all of my devices (6 of them, A-F)
A
Closed: 050A847B
Open: 050A04FB
B
Closed: 8F80847B
Open: 8F8004FB
C:
Closed: 919E847B
Open: 919E04FB
D...
That sounds like what the demo app is showing, but I do NOT see the same protocol as evidence by plugging my W800RF32 up to my scope or to my AVR. My scope and AVR both show 4 bytes (actually a few DS10A's only send 3 bytes; which is really odd). And none of the bytes are compliments (which...
I hadn't seen the RF documents before. Only WGL's protocol, which doesn't match what I see. Even if they reordered the bits. None of my bits are the inverse of any of the others. Perhaps the DS10A's use an old standard.
Does the RF message mirror the serial message?
Regardless, I can't...
Hey guys,
A little off-topic but I am trying to ID 6 sensors with a microcontroller (atmega168) wired up to a W800RF32. Right now I am trying to decide what bytes each device is sending. I started using the demo software that came with the w800 but it shows 4 bytes that aren't even close to...