Recent content by jim3342

  1. J

    Beer monitoring?

    Ummmm....for some reason I feel a little hijacked?!? I could have sworn I asked for a flowmeter and we were fine with OUR software....thanks for the plug though...
  2. J

    Beer monitoring?

    I have a friend who owns a small pub and would like to understand where all his draft beer is getting 'lost'. Anyone know a good flowmeter I could use for the lines that go from each keg to the tap? Software would be easy enough but I need a flowmeter that would work with either an analog...
  3. J

    Brultech ECM-1240 Software Development

    We have great support for the ECM-1240 and the ISY for a total energy management solution. www.check-it.ca
  4. J

    upgrading from 'well water' to 'municipal water'

    How about monitoring water quality as well as consumption? Everyone has been talking about high iron or other minerals, is there anything out there that is a simple install like the DLJ meters but also gives some type of serial output on quality reading?
  5. J

    New Brultech Energy Monitoring Model (ECM-1240) due in 2009

    It is not that it isn't easy but more of an issue with having to purchase 2 etherport gateways as opposed to just one etherbee for wireless. You would run a CAT5 cable to each etherport and it would take 2 ports in your router. Each etherbee would have it's own IP address and report to...
  6. J

    New Brultech Energy Monitoring Model (ECM-1240) due in 2009

    Wireless is not only a better option if you can't run a wire, it is also beneficial when you want to use 2 or 3 monitors with one gateway. With our online demo (www.check-it.ca) we are actually running 3 monitors through one gateway. We also just finished an install on a farm that had one...
  7. J

    Web hosting offer with BrulTech ECM-1240

    The Google meter is relying on the implementation of the smart grid from GE. I've worked with power utilities long enough to know that type of implementation doesn't happen too quick. When it does happen it will not break it down to anything but the overall usage.
  8. J

    Web hosting offer with BrulTech ECM-1240

    We are working on a new feature on our site that will allow anonymous comparisons of the channels on the ECM-1240. It will allow customers to compare their circuits to all other devices that are named the same. For example, we will take the average of all channels named Clothes Dryer and let...
  9. J

    New Brultech Energy Monitoring Model (ECM-1240) due in 2009

    Anyone interested can also email [email protected] for further information.
  10. J

    New Brultech Energy Monitoring Model (ECM-1240) due in 2009

    Neurorad, Just a reminder that there is no actual data collected on the site with the new ECM-1240 installed with the gateway. All data is sent to our hosting centre and there is no dedicated PC required at the install location. Our monitoring fee is very reasonable considering reports are...
  11. J

    New Brultech Energy Monitoring Model (ECM-1240) due in 2009

    We haven't posted prices because Brultech is just finalizing hardware costs. Anyone interested in the discounted monitoring rate for Cocooners can PM me.
  12. J

    New Brultech Energy Monitoring Model (ECM-1240) due in 2009

    Our company has been working with Brultech on the development of the ECM-1240. We have developed a web-based service for the monitoring and data storage for all 7 channels on the device. We are willing to provide a discounted Cocooners rate for anyone wanting to use our service after...
  13. J

    W800RF

    Has anyone used the W800RF over ethernet using some type of serial to ethernet device? I would like to have all the received serial data from the W800 forwarded to an IP address and port number. I would like to avoid having a virtual com port as I plan to have multiple W800's installed...
  14. J

    Electricity Monitoring

    I'm not saying it should be taken lightly at all. My point is that I've already done the poking around and it's in place. So is there anyway these CT's can cause other issues?
  15. J

    Electricity Monitoring

    I can appreciate the fact of touching a live wire and I've been really careful about that. I'm now a little concerned about the CT's near the panel. I've put a CT on line A & B from my diagram and it seems to be giving accurate readings. It will take a few days to know for sure but do I...
Back
Top