Recent content by racerx90

  1. R

    Caddx Key FOB Function Buttons Question

    Looks like this is not possible after talking to some Networx/Caddx experts. 1 Button can only do 1 event - there's no differentiating between keyfobs.
  2. R

    Caddx Key FOB Function Buttons Question

    Has anyone programmed their Caddx NX-470 Key FOB Function Buttons for controlling devices? I've got a Caddx NX-8E panel and with a NX-540E expansion module for event and X10 control. For the most part I think I got the device control part of the programming down. In my case, I'm using a button...
  3. R

    Key Fob's

    If you have the ITI/Caddx NX Wireless board (NX-448E/548E) on your Elk, then you probably can just use the ITI/Caddx NX-470 4-button keyfob. It's pretty small and please correct me if I'm wrong (since I don't own an Elk system myself, but I do know the ITI wireless board works with that system)...
  4. R

    CADDX NX-8E system advice

    There's a poor man's way of doing it, but what you can do is take the sensor after you enroll it and have someone stand at the keypad and use the *^ (up arrow) to scroll through the zones until you find the wireless zone you're looking to monitor. Make sure the sensor is not tripped (meaning if...
  5. R

    Sulfur Dioxide Sensor

    This is honestly one of the more creative posts I've seen in a while. And yes, I got a laugh out of it...
  6. R

    CADDX NX-8E system advice

    While programming isn't the easiest IMHO (even though I'm fairly good at it and I don't use DL900), once you get use to it then it becomes second nature. I'm on my second installation of a Caddx system (running an NX-8E now) and I really like the flexibility of options. There's a board out there...
  7. R

    caddx nx8e resetting to factory defaults?

    To default a device: *8 + <Programming Code, the default is 9713) + <Device ID, the panel is 0># + 910# Remember, EACH device has their own factory defaulting option, meaning if you default the main panel (0#), the wireless board for instance (32#) won't be defaulted. You need to specify that...
Back
Top