    PLC solar inverters and UPB

    Hello,   There is a possibility that a single power manager could work with both sites if they are as close electrically as you think.  The PLC signal will travel through electrically adjacent houses.  That is why the microinverters are paired with a power manager after discovery to prevent...
  2. S

    PLC solar inverters and UPB

    A great question. We do have API's for our OEM module customers.  The API is under non-disclosure agreement.   If you want to develop for the SolarBridge API please contact us at SolarBridge or we can take this topic off the forums. 
  3. S

    PLC solar inverters and UPB

    INSTEON uses Modulation: Binary phase-shift keying (BPSK) at 131.65 KHz which is away from our 110KHz  FSK system.  We have not done any testing at SolarBridge but it should work well due to difference in frequencies.  We originally based our technology on ST microsystems, but have made...
  4. S

    PLC solar inverters and UPB

    The SolarBridge PLC system uses Frequency Modulation (AM) and the UPB system uses Pulse-Position Modulation (PPM) so the devices should not interact with each other.  SolarBridge has done informal testing with X10 systems, and there was no interaction. That was with the SolarBridge system in a...