Recent content by sowhat

  1. S

    Zone and tamper doubling on NX-8

    yeah, you are probably right, but I can use tampers anyway, only system won't distinguish movement from tamper opening. Now I have new problem, please pay attention to may previous post.
  2. S

    Zone and tamper doubling on NX-8

    Latest news: I changed zone type to 6 = INSTANT - This zone creates an instant alarm whenever it is tripped and the Armed LED is on. And everything works fine except one thing - system reports "Service required, Type *2 for help" And *2 reports that zone 14 is tampered. How to take away...
  3. S

    Zone and tamper doubling on NX-8

    here you can take a look at NX-8 install manual. Zone doubling is very cheap way for extending your panel ;) As I understand in my wiring, there should not be any difference between cutting detectors wire and opening detector, because tamper contact resistance is so small (0.01K). Default...
  4. S

    Zone and tamper doubling on NX-8

    yes, they both are on channel 6. Zone doubling enables adding 16 detectors to 8 chanels ;)
  5. S

    Zone and tamper doubling on NX-8

    thanks for replay! I don't know resistance levels B) they aren't mentioned in users manual, but I will measure what I can. So here it goes: No movement: 2.73K Movement on zone 6: 3.66K Movement on zone 14: 6.70K Tamper open on zone 6: 6.72K Tamper open on zone 14: 3.67K here is a little...
  6. S

    Zone and tamper doubling on NX-8

    why nobody helps me? :) B) :(
  7. S

    Zone and tamper doubling on NX-8

    Hello! I am really stuck for few days on trying to add ninth detector to my system in the garage. I connected new detector to zone 6 and replaced old resistor with new one 3.74K for doubling and also added one more resistor 6.98K in the new detector. Turned on zone doubling and selected zone 6...