  1. T

    Better way to temporarily install EOL resistors

    Did ADT run 2-wire or 4-wire for the doors ?  If it is a 4-wire loop then you can fully supervise and yet have the eolr in the control panel, just use 2 wires for the tripping circuit and the other 2 for the eolr   
  2. T

    Motion Sensor Testing

    I have found that pet immune motion detectors work well with smaller dogs, and some up to even 80 Lbs., but cats are another issue . I would like to suggest replacing your motion detectors with glass breakage sensors which will provide protection in the event of shattering glass, but allow for...
  3. T

    Wired sensors tripping

    You either have a problem with a faulty sensor or damaged wiring. You could remove the sensor and short the wires at the door to determine which. Also check the resistance of the wire run to verify proper resistance to the loop. Is the magnet installed in a metal door? A magnet installed in a...