Recent content by asnopek

  1. A

    Has anyone been able to download the 3.15 firmware version?

    With the new release of PC Access it worked.
  2. A

    Has anyone been able to download the 3.15 firmware version?

    Hello, Has anyone been able to download the 3.15 firmware version?  I have dealer PC Access but when I get the option to download the screen doesn't scroll (see attached image).  
  3. A

    Sending commands to HAI OmniPro II based on Geo-fencing

    Hello,  Is there any way to do the following? If I come within a certain proximity of the house with my phone, I want the lights to turn on or issue other commands.     My friend can do this with IFTTT and Philips Hue.  
  4. A

    Can not update "Unvacated Premises"

    I can change the settings and "write" them to the Omni but they don't persist.  When I read them from the Omni I see the old configurations that the dealer version wrote. 
  5. A

    Email board not working HAI,

    Figured it out. Need dealer version to do this.  Personal version persists the emails and messages but not the check boxes, that's ridiculous. 
  6. A

    Can not update "Unvacated Premises"

    Figured it out.  Need dealer version to do this. 
  7. A

    Can not update "Unvacated Premises"

    Hello,  I am trying to set "Unvacated Premises"  to No.  I go into PCAccess and I wrote EVERYTING to controller.  Then I retrieve everything from controller and the setting doesn't persist.   I own the user license only not dealer for PCA,  do you think that might be the issue?    I posted...
  8. A

    All off - Scene execution

    I have the user license of PC Access and I do not see the column.  Should have gotten the dealer version. 
  9. A

    All off - Scene execution

    Hello, I pressed all off by using the key pad "4 then 0".  When I do, I get the following scenes executing (enclosed image). Does anyone know where do I go to edit this list (upstart, pcaccess)? [sharedmedia=gallery:images:806]  
  10. A

    Email board not working HAI,

    Hello, I have an email board attached to my omni-pro II.  I check the check boxes for events such as arm/disarm, alarms, troubles, etc.. then I write it to the controller. When I read from the controller the checkboxes disappear except for the first row email in the "user message", which is the...
  11. A

    Need help with Room Status Switch

    I ended up with the following. In PcAccess, automation code to set flags and set the LED on and off.   51.    WHEN ENTRY HALL ON     WHEN FIRE RECESSE ON     WHEN FIRE ACCENT ON     WHEN CHANDOLIER ON     WHEN CEILNG ACCNT ON     WHEN OUTLETS ON             THEN INCREMENT 1ST Floor East Flag...
  12. A

    Need help with Room Status Switch

    Figured out # 1) I would like to reset the flag to 0 in case someone presses the switch down or up twice or something like that.  The flag at that point would be in an inconsistent state.   // when scene 109 off then sett flag to off 2.    WHEN UPB LINK 109 OFF             THEN 1ST Floor East...
  13. A

    Need help with Room Status Switch

    Hello, This is what I did so far to test one room and it works.  Not great but since I don't know what I am doing it's the best I could come up with.   I am incrementing or decremening a flag if the top or bottom switches are pressed, repectively. Using PcAccess 1.    //    1st floor east room...
  14. A

    Need help with Room Status Switch

    Unit 33 is a 6 button Room Controller that controls only the east room. The 8 button status switch is in another room, which is the one I am trying to enable to control the entire house.   The Id is 158.    [sharedmedia=gallery:images:798]
  15. A

    35A00-1CFL 600W Timed Auto Shut Off not working

    Here is the screenshot but this feature doesn't work.  If this is accually a defect, I am surprised it wasn't resolved.  Especially, given the price of these switches. [sharedmedia=gallery:images:797]