    looking for rain sensor

    Thanks. What would be the best way to make it "visible" to my HAI controller?
  2. J

    looking for rain sensor

    I realize it's been a while on this thread, but I'll try anyway. I recently installed a Rain8UPB Pro irrigation controller. We did not install a hardwired rain sensor. I have an HAI Ominpro IIe home automation system and a UPB network with lights and thermostats interfaced to the HAI. I am...
  3. J

    PC Access3 can't connect to OmniPro IIe after new router

    One more thing. I had to juggle some power cords around so that everything would fit into the outlets and power strips so I may have briefly removed power from the OmniPro, but I wouldn't think that would be a problem. I'm sure the OminPro is working because I can see everything from my touch...
  4. J

    PC Access3 can't connect to OmniPro IIe after new router

    My cable company made me upgrade my cable modem. The old one had a built in router with wifi. It was in the basement and it didn't have a very strong signal, so I installed a separate wireless access point on the first floor. The new cable modem came with a separate router. I installed...
  5. J

    Can't program my Omnistat 2

    I have 4 Omnistat 2 thermostats connected to my OmnoPro II. When I push the scroll wheel on an Omnistat 2 to display the Main Menu, the only options I get are Setup and Run Time Graph. I don't have a Program option. I used to because I did program them all once. They are all set to "Energy...
  6. J

    HLC for non-HAI UPB lights

    Thanks for clarifying. I'll give it a shot.
  7. J

    HLC for non-HAI UPB lights

    I did read that article and the attached spreadsheets. I'm still not entirely clear and I wanted to double check before I go and rework my 50 or so UPB devices. The spreadsheets imply that HLC assumes that certain devices are Room Controllers and others are House Status Switches. Can I have...
  8. J

    HLC for non-HAI UPB lights

    So, If I change all of my UPB Units to HLC, I will have to renumber some of them since HLC assumes that units 1, 8, 17, etc. are Room Controllers and thus have no load.  Do I also have to organize my switches so that devices within a physical room are grouped according to the HLC convention...
  9. J

    HLC for non-HAI UPB lights

    I have an Omnipro II with motion sensors, door sensors and with Simply-Automated UPB lights. My contractor configured the lights with UPStart and then put names into PCAccess for each of the units. HAI units 1-55 now correspond to UPB devices 1-55 in UPStart. I have programmed many links into...
  10. J

    HAI Programming help

    It's Flag 1, Unit # 393. Block 8 is the only place where that flag is being set. Block 9 is the only place where that flag is being checked. I have the latest PCAccess version and the latest Firmware. Not sure exactly what version it is because I'm at work right now and can't check it, but...
  11. J

    HAI Programming help

    I have an HAI OmniPro II controller and Simply Automated UPB switches. We also have a motion sensor in the kitchen. I'm starting out small here. All I want to do is have the kitchen lights turn off automatically if there is no motion in the kitchen for 10 minutes unless the accent lighting is...