Recent content by kellyjsanders86

  1. K

    "No Controller Data" on OMNI II to OPII upgrade

    Strange... after having a Omni Pro powered down overnight the new keypad that worked last night did not work today Until I unhooked the sirens and re connected to power. I also did a 9 volt keypad self test and all three past. I'm stumped. Full connection to PC access software is OK. I...
  2. K

    "No Controller Data" on OMNI II to OPII upgrade

    Update: I tested each keypad individually (Direct connect) and two out of the three show 'No Data'. one works fine. Strange that all three work fine with the Omnill so all wiring can be elliminated. 3 work with Omni ll 1 works with OmniPro ll this points to a versioning issue from my standpoint.
  3. K

    "No Controller Data" on OMNI II to OPII upgrade

    thank you very much for the quick reply. I think I will check all three keypads to see if they work independently, tied to the controller. I also believe that I should buy a fourth Keypad to swap in and out to verify. I'll also get in touch with tech support. Thank you. Strange that the exact...
  4. K

    "No Controller Data" on OMNI II to OPII upgrade

    Having the exact same issue right now. Omni ProII works correctly except consoles show no controller data. Did this have an outcome? Same exact wiring as OmnoII which still works successfully with consols. Could it be a firmware verson mismatch between the two controllers and the keypads? Thanks
  5. K

    Premise HAI Buttons (macros) and Premise

    Looks like HomeSeer has a way to connect the HAI Omni 'buttons' through to trigger their stuff.  I also found a package at Autonomic that will connect Omni buttons to Media Center to trigger actions.  Would love to do this with Premise... maybe Event Ghost?  But still need to see Omni soft...
  6. K

    Premise simple HVAC setback using Schedule/Scene

    I started getting very odd temp readings (300+) for set points within premise (house level) when I had the stat added to a Premise scene.  So I'm back tracking to see at what point this goes wrong.   For now I did add the logic in the PC Access within the Omni panel.  Wife is happier waking up warm.
  7. K

    Phone access, hookup to OPII

    I have tried reversing the wires on both sides of the connector.  This is my second panel (2nd house) so I know the drill.  The most success has been to have the panel LED show the correct status (and PC Access) with the phone on/off hook.  And if I remove the panel from the path (directly...
  8. K

    Premise Z-Wave Status using RZCOP/VRCOP help

    Looks like my zwave lighting configurtion is settling in. 18 errors in 7600+ jobs. Very good!  I had to re-optimize the network after a VRCOP lock up, then update everything.   The module is still automactially increasing the one-way polling time when, after 3 misses, it resets the comm port.  ...
  9. K

    Premise HAI Buttons (macros) and Premise

    Am I missing something or did the HAI Omni soft 'Buttons' not get included with the Premise module?    
  10. K

    Premise HAI, Premise, XBMC

    etc,   I lost track of this thread. Still certainly something I want to do and with the latest XBMC release (Frodo) they now have cool ipod, ipad, android, apple TV, and even Raspberry Pi images. and of course Windows, Linux, and iOS. The skinning community is still growing so the UI's for each...
  11. K

    Premise Premise and EventGhost?!?

    what a great way to pull-in more Premise users!  I was just playing with XBMC's latest release and wondered why I couldn't have a Premise Browser control screen embeded in XBMC.  Of course the UI would have to match the XBMC out-of-the-box theme.  What you're working on is just another way to...
  12. K

    Premise simple HVAC setback using Schedule/Scene

    Desert_AIP,  thanks but I'd like to keep all the logic (as much as I can) in Premise.   etc6849,  You're always so helpfu.  Thanks!  I thought something strange was happening when I added the tstat to a scene.  But that is really what we should be doing.  Just like a scene for the home...
  13. K

    Phone access, hookup to OPII

    did you get this resolved?  I'm getting the same issues using a Obi202.  HAI phone led behaves correctly but does not seize the line and no phone control.  On hook is showning on-hood and off hook showing off hook in PCA.  Phone also operate correctly.   I'm also in Washington.   Ideas?
  14. K

    Premise simple HVAC setback using Schedule/Scene

    So... I may be lame here but I don't see an easy way to control my HAI Omni stat heatsettemp with a schedule. I'd like to have the schedule set to 70 and when the schedule is off to set back to 63... but come up to temp of 70 if the house shows occupied. I could do this with two schedules but...
  15. K

    Premise Z-Wave Status using RZCOP/VRCOP help

    Great! Thank you. When I finish this part I'm moving on to lighting ramp control. I'd like some of my scenes to ramp much slower (mock sunrise). Thanks much for the support!
Back