Interesting issue, but at least the APP still works.
Updated from iOS 17.7 to 18.2 on both iPad and iPhone and they both removed the wallpaper (Default Blue), and turns background to Black. I found an old Wallpaper for iPad that has high contrast, but can't seem to find the original "Blue...
Never mind,
I did indeed find where I can remove from Setup. Interesting the iCloud version maintains your settings, even though you don't backup to the iCloud. If I get a chance, I will post where to delete the camera. I had the same issue with SPACE, but finally was able to override MJPG...
I know Snaplink uses MJPEG camera feed, and noticed when accessing camera from SnapLink app it disconnects camera from Synology NAS.
I can't seem to delete camera from Windows app or iOS.
I can hide in iOS but not delete! I deleted the app from iPhone and downloaded again, but it's still...
I know this is a late reply. I purchased for around $10.00 in 2022, don't know if Windows version was ever released free. You have to use Microsoft Store to get it.
Again apologize for such a late response, until 3 weeks ago, I didn't have Ethernet access to my controller, so I haven't tried...
That seems to be the case. I was just bringing up a replacement controller and forgot to update PC ACCESS on my old laptop with built-in Serial Port, used to test MODEMS and other devices. It crashed when I went to set the clock, using Ethernet X-OVER.
I recalled Leviton released two...
Sorry for late reply, two "WHEN" triggers (version 3.x or later FW) should Work Fine as you experienced.
The "OR" function shares the trigger Event" with an additional AND Condition such as:
WHEN Mudroom Door NOT READY
AND IF DARK
OR
AND IF Entry_Steps ON...
@ano, thanks for reply. It seems when I purchased Snap-Link I rarely used it, and then my Controller started having Ethernet issues so I rarely looked at it. It does indeed show UPB status, but as "Scenes" and lacks detail when Unit is on Timer (unlike SPACE).
I posted Images comparing...
I just went through the painful Process replacing my OMNI II PRO 2002 Vintage controller, due to failed Ethernet PHY. I purchased a USED OMNI PRO II (Flashed 4.0B), and can now successfully communicate through the GL.iNet router (@pete helped with this) with good TCP communications.
I have been...
Hi Pete!
Yes, I plan to wire in a console to see FW version and set IP Address. I received confirmation from vendor yesterday they RESET THE ROM & RAM prior to shipping.
I know there were lots of changes to the board, some including a daughter card above U29. My printed manuals are from JAN...
Since I have had Ethernet issues on my original HAI OMNI II PRO, I purchased a USED updated controller, with the FLASH (EAROMS) under U29 & U30. It did not come with a manual, and the only manuals I have from many years are based on the old design I purchased in 2001 (USES EPROM).
Does anyone...
The version I have is 3.17.3.861 which Leviton released to fix Date & Time issue in 2020.
By the way Malwarebytes Browser Protect Cautions the download?
I have purchased several PCS UPB Receptacle Modules (15 AMP) the last three years (unfortunately I haven't had the spare time to install and implement). I have been a fan of the application notes they have on there website geared to PCS/OMNI II Integration.
I need to address the lack of...
Not complete convinced jumpers are the issue. I just was messing with DMZ router for OMNI II Network Interface and SMOKES had trouble again. I moved Power Supply for Gl-iNet Router to first Auxiliary 12V power screws, and now loop is reporting good. Something seems intermittent with the OMNI...
I think I found the issue......
Some time ago I strapped Zone 3 & 4 for "NORM", and left ZONE 1 & 2 for "SMK" (JP11 & JP12).
I decided to put JP11, JP12, JP13 and JP14 all in "SMK" position, since I already moved Water Moccasin sensor to ZONE 33 (Expansion).
I wonder if any zone, between 1...
Well no answer, but below is a list of steps I have taken:
1) Replaced EOLR with New One, I didn't think this would help (it didn't).
2) Moved ZONE-1 to Zone 2, no change Loop still reading "4" (Zone-1 used to read 33 when working before adding Water Moccasin Zone-3)
3) Removed ZONE wires from...