    Hard-Wired Lighting Control Recommendation

    I used Centralite Elegance in a 9000 sq ft home and love it. Have had no problems and used my local electrician to wire it in. Bought the system from a local store, programmed it myself and am proud of it. I would recommend it to anybody. The only problem I have is when my kids, 11 & 8 have...
  2. 2

    4WTA-B Smokes

    I guess my question now is if I wire the 4wtba smokes as a 2wtba and zone in a group of four sokes per zone would I use the EOL used for the 4wtba or the 2wtba EOL relays? Still trying to wrap my brain on how to wire these since they are home runned and i already have the 16 detectors. I am...
  3. 2

    4WTA-B Smokes

    so what is the recommendations for wiring these detectors to the Elk? All of my wires were home run and I have 16 detectors. I'm open for suggestions.
  4. 2

    4WTA-B Smokes

    How would I wire it as a single loop if everything was home runned? Would I need EOL on every smoke?
  5. 2

    4WTA-B Smokes

    Dont know if this helps but I built a new house and home run all cables including the smokes. Had I dont it all over again I would have daisy chained. I dont have all my smokes working (Temporary Battery Smokes now) but here is a diagram I had someone help me with using the Elk system. Should...
  6. 2

    LED lighting and Low Voltage Distribution

    Did you replace the fixture or just the bulb? I have four LED landscape fixtures and it is a bright white....kinda harsh but lights up good. Wondering how you switched to a Soft White?
  7. 2

    ELK and Extra Power Supply

    Are you talking about this for the power supervision relay? http://www.automated...t.A/id.29660/.f or http://www.automatedoutlet.com/Home/Relay-Modules-Timers/ELK-912
  8. 2

    ELK and Extra Power Supply

    I ran 4 wire firewire cable (Standard smoke wire) . I would add a EOL resistor at each smoke.
  9. 2

    ELK and Extra Power Supply

    All of my wires are home run to the automation room. So I wont be able to daisy chain the wiring.
  10. 2

    ELK and Extra Power Supply

    Finally have time over the holidays to finish my wiring project. Attached is the schematic of the wiring diagram for 16 system sensor 4WTA-B smoke detectors to a separate power supply. Using the M1G. It is a large house and am wanting all smokes to alarm when one smoke activates. Also want...
  11. 2

    ELK and Extra Power Supply

    Added image to gallery of diagram of layout for the schematics.
  12. 2

    ELK and Extra Power Supply

    Hi everyone, Newbie here trying to wire a Elk M1G with 16 Smokes along with approximately 60 zones, 4-5 Temp Sensors and a Elk WSV (Water Shutoff Valve). Because of the power requirements I am using a Elk P412 four amp power supply. The smokes are the System Sensor 4WTA-B. All smokes are...
  13. 2

    The geothermal discussion thread

    Spray foam was a no brainer for me. I have 9 foot walls on two floors and 8 foot on the 3rd floor. With the size of the house and the reduction in tonnage for the geothermal saved me 4 tons of geothermal. It cost me $14,000 for insulation (Walls and ceiling). It was going to cost me $10,500...
  14. 2

    The geothermal discussion thread

    Hey guys, wanted to chime in on the geothermal. I built a new 9000 sq. ft. house with 7800 heated/cooled last year. Have lived in the house over a year and my average electrical bill is $225.00 per month. I have two 4 ton geothermals from waterfurnace. I used foam insulation in walls and...
  15. 2

    Audio Authority

    How did you program the crestron and the mx remotes? Was it done by a custom installer or was it done by yourself? I didnt think URC provided the programing for the remotes?