Recent content by cowger

  1. C

    M1G Rebooting

    I posted last month about having this same issue (random reboots) and around that time upgraded to 5.3.8.  At that same time, I upgraded my keypads and Ethernet expander all to the latest.  Since then, I haven't had a reboot.  (I added a rule to have it e-mail when it reboots, which works.)  ...
  2. C

    M1G Rebooting

    And I'll add my name to this list.  About every other day or so my alarm panel reboots, with the same, lone 1367 message in the log.   I just updated to 5.3.8 but, based on this thread, I'm not optimistic that this will fix anything...
  3. C

    Elk M1 -> RS232 -> Lutron Illuminations: Newbie questions

    Success! Finally.... For anyone who hasn't blocked / unfollowed / auto-ignored this thread, here's what I learned: 1) The XSP MODE jumpers definitely override BAUD rate selection. 2) When in a selected mode, e.g. Lutron RA, the XSP will function as a general purpose Transmitter but NOT a...
  4. C

    Elk M1 -> RS232 -> Lutron Illuminations: Newbie questions

    Another update: In scouring through the XSP manual again this morning, I noticed one little line at the top of the table on the last page, which essentially states: "To use the M1XSP as a Serial Port Expander, set the MODE jumpers to 1,0,0,0 (S5...S8) and then set BAUD jumpers according to the...
  5. C

    Elk M1 -> RS232 -> Lutron Illuminations: Newbie questions

    Update1: I also tried sending the string "armstay" directly from the terminal emulator into Elk. Nuttin'. I can get Elk to output to the screen of the emulator, but it simply won't respond to anything I send in. Update2: I see in the software that the input string must end with CR. I have...
  6. C

    Elk M1 -> RS232 -> Lutron Illuminations: Newbie questions

    Thanks, drvnbysound. I did try power cycling, but it's hard on 9600. It works, so oh well. On to the next challenge... So I have comms working from Elk -> Lutron; now I'm trying to get the reverse to work. I've programmed the Lutron system to send the text string "armstay" to the Elk, and...
  7. C

    Elk M1 -> RS232 -> Lutron Illuminations: Newbie questions

    Well, months later, I finally got some time to get a Serial Expander added to my system today and get it interfacing to my Lutron system. As Work2Play points out, it took a little trial and error but I eventually got it working. Now I can control any light or load in the house based on alarm...
  8. C

    Elk M1 -> RS232 -> Lutron Illuminations: Newbie questions

    BTW, what thermostats are you using? That's my next upgrade...
  9. C

    Elk M1 -> RS232 -> Lutron Illuminations: Newbie questions

    Thanks, I will definitely keep your offer in mind. Here's a sample command that Lutron is looking for, which seems pretty straight-forward to implement as an Elk text string: KBP, [01:01:06], 02 (with a carriage return, 0xd, immediately after the 2) followed by: KBR, [01:01:06], 02...
  10. C

    Elk M1 -> RS232 -> Lutron Illuminations: Newbie questions

    Ah-so -- thank you so much! This does make sense now but I doubt I would have stumbled into this without the pointers. I'll play around with this and let you know if I have any further questions. Greatly appreciated! Bryan
  11. C

    Elk M1 -> RS232 -> Lutron Illuminations: Newbie questions

    Hi, After 11 years, my old Lutron HWI system bit the dust and I recently had a new Illuminations processor installed. Since the new Lutron processor has Ethernet built-in, it has freed up an RS232 port which I'd now like to connect to my Elk M1. The purpose is to have the Elk send serial...
  12. C

    Generic Elk M1G e-mail config

    Hi -- just joined and thought I'd post what I did for a generic e-mail configuration for my new Elk M1G. I did a search, and it appears that many people have difficulty getting e-mail to work with their existing ISP. I did, and while I know many people have solved this problem one way or...
  13. C

    Elk M1G config question

    Thanks, guys, for the help. A more diligent power-down / re-config methodology took care of it. Now I know... : ) Bryan
  14. C

    Elk M1G config question

    Okay, so here's what I've tried... I set the expander back to address 3 (just switching while everything was powered on), and then re-enrolled everything. Then I unplugged the expander, re-enrolled everything, switched it to address 2, plugged it back in, and then re-enrolled everything again...
  15. C

    Elk M1G config question

    I did not -- will try that tonight and see if that helps. I actually just made the address change "hot" in the system, which was probably a dumb thing to do. I'll do the reconfig more formally and see if that helps. Bryan