Recent content by iprowell

  1. I

    Experience with the Elk two way listen in interface

    I’m considering adding a two way listen in interface to my M1 gold so that I can have additional audio outputs. Does anyone know if the audio output to the additional speakers is the same as the main board speaker output? E.g. announcement of arm/disarm, alarming, etc...
  2. I

    Central Monitoring

      What does AlarmRelay support using the ElkM1 and XEP? I'm primarily looking for 24/7 monitoring to contact emergency services police/fire in the event that I am not responding.
  3. I

    Smoke/Heat/Fire with existing wired smoke detectors

    We had to have conventional wired smoke and CO2 sensors that are not tied to our alarm system based on local requirements. I have two/three objectives; add some smoke/heat sensors near the battery backup system we have, and to monitor our smoke/co2 detectors and fire sprinklers with our alarm...
  4. I

    2019 Glass Break Detect

    I am looking for a low profile wired glass break sensor. Does anyone have experience with the Honeywell FG-1625F? How about the Bosch DS1103I?   Thanks!
  5. I

    RS485 bus wiring

    Mike, Thanks for the input. The intent of the DBH was future flexibility. Nearly everything on the data bus will be in a single cabinet and will be on a single leg of the bus. Right now I only plan to have one keypad off the DBH. Maybe I can just use the DBH for initial testing and keep it at...
  6. I

    RS485 bus wiring

    The only long run will be for a M1KPAS so even lower draw than the M1KP2. There will be a M1KP near the main unit and I will probably just use 4 wire to that with it terminating the "local" leg of the bus.
  7. I

    RS485 bus wiring

      I went through the spreadsheet and am well under the 1 amp limit. Thanks for pointing that out.   Right now the only remote items on the RS485 bus will be 2 keypads. I'll give it a go with standard cat5. The 22awg was spendy and going to take a while to arrive. I have dealt with crimping down...
  8. I

    RS485 bus wiring

    I am starting to wire up my expansion boards onto my Elk M1. I have a M1DBH. On hand I have shielded 18/2, shielded 18/4, unshielded 22/6, 26awg cat5, 24awg cat6, and probably a few other sizes.   - Should I wire the M1DBH directly to the M1G with everything, even local expansion boards off the...
  9. I

    Elk M1 in a Leviton Enclosure

    Thanks for the information. I thought my setup was overkill, but I guess I am not the only one who wants reliable wired sensors.
  10. I

    Elk M1 in a Leviton Enclosure

    Hello All, Our place is setup with a Leviton structured media enclosure where all the sensor wires go. Obviously I will not be installing an Omnipro. Are there any pointers to get the Elk M1 equipment into the Leviton enclosure? It looks like it will involve a lot of drilling.   Thanks, Ian