    Elk M1 with Alula Bat-Connect

    Anyone? Seems no one is using Alula. 
  2. P

    Elk M1 with Alula Bat-Connect

    Does anyone have experience using the Alula Bat-Connect A with the M1? They are marketing for many legacy security systems. They specify auto switching for the triple path connectivity. I'm curious if anyone has used it with ethernet and cellular?  How useful is their App & what features on the...
  3. P

    System Sensor Cosmod 4W

    I have a new ELK M1 installation with System Sensor COSMOD4W module, and using a mixture of i3 smoke # Cosmo 4W and i3 #4WT-B. I am using a SS ELOR-1 relay for reset & all units sound in both the 3 & 4 temporal modes for smoke & CO. The smoke and CO sensors trigger in test mode & the Cosmod 4W...
  4. P

    Multiple Parallel Power Supplies for Elk M1

    Thanks for your feedback.    Re # 5: The reset command will break power output to SAUX - my ELK 912 relay NO to Altronix NO will drop power to the COSMOD 4W and allow reset of either " smoke" or the "CO" sensor alarm condition to allow the reset.   Re # 6 - to activate sound from sensors -...
  5. P

    Multiple Parallel Power Supplies for Elk M1

    Thanks for your responses. After further consideration & reading I am rethinking how I should proceed for the smoke/ fire / co on this project. Let me recap:   Existing house wired with 5 separate 8 fire wire circuits to the alarm panel. I am in the process of upgrading from a 17 year old...
  6. P

    Multiple Parallel Power Supplies for Elk M1

    Thank you.  I will plan to use SAUX to ELK-912  to  Altronix AL600ULACMCB using the FACP - N.O. trigger input on the Altronix.    The existing -Napco FW4 or FW4-H smoke sensors (11) are wired in 5 separate circuits to the module board. The ELOR-1 & 2.2K resistor will allow supervision. If all 11...
  7. P

    Multiple Parallel Power Supplies for Elk M1

    I am planning Elk M1 install for and existing home with 5 separate smoke / heat sensor zones with Napco FW4 or similar. All sensors are wired with 8 conductor fire alarm rated cable. Per the Elk power spread sheet, it computes 1.53 total amp draw for the total of 11 smoke sensors- and other...