Recent content by little66085

  1. L

    WIRELESS INTEGRATION OF PHOTO ELECTRIC BEAMS TO ELK

    Can anyone tell me if I can install exterior photoelectric sensors and connect them with any type of wireless ELK device to notify panel?  I cannot get a wire from the exterior to the panel.  Thanks!
  2. L

    INSTEON MOTION DETECTORS FLASHING

    Can any one tell me why I have several motion detectors that are linked directly to a switch that flash rapidly every minute or so?  The are operation, but I cannot get them to stop flashing.  Removed battery re linked, tried to restore via ISY, but nothing works.  One is used for dusk to dawn...
  3. L

    ELK M1 SETTING CHIME ON SCHEDULE

    Hello, Is there a way to set the zone chime to only be active during night hours?  I cannot seem to find a way to do it.  Thanks!
  4. L

    PHOTOBEAM WITH ELK M1

    Can anyone tell me if there is a way to install a NO or NC photobeam wireless to my M1?  Would like to have it signal the system same as a door sensor (beep at keypad)  Thanks!
  5. L

    M1XEP HELP

    Well, you confirmed my suspensions.  My router does not show it as a connected device, I have 12+v power and swapping the cat6 is not helping.  I do have an orange light on the XEP and cannot remember if it was always that color.
  6. L

    M1XEP HELP

    Hi all, Suddenly, my M1XEP became invisible.  RP cannot locate it.  I have rebooted the internet and re-powered the M1XEP but no luck.  Any ideas?  Thanks in advance for your help!
  7. L

    ELK Wireless Smoke in addition to System Sensor

    If I am understanding, both the wired and wireless will work independently, but both will trigger the fire alarm, correct?
  8. L

    ELK Wireless Smoke in addition to System Sensor

    AUX Power Resettable would be SAUX   4 Wire IDC would be your fire zone. e.g. Zone 16 JP1 jumpered for Normal. Or use any other zone.   MAINT/FREEZE IDC would be any zone input, configured as the trouble zone.   AUX Power would be VAUX   Bell/Alarm Circuit would be a relay output (e.g. OUT3)...
  9. L

    ELK Wireless Smoke in addition to System Sensor

    Can you explain how to write the rule?  I have the smokes wired to the NO on OUT3  and rule to send alarm if triggered.  Also have a strobe connected to OUT3.
  10. L

    ELK Wireless Smoke in addition to System Sensor

    Thanks.  I have a similar issue.  I need to install a smoke detector in my garage and laundry room, but the upstairs is finished so I have no way to run the loop.  WIreless is my only option.
  11. L

    ELK Wireless Smoke in addition to System Sensor

    Is it possible to install 2 wireless smoke detectors to work in conjunction with wired SS smokes?  I have the SS wired into my elk using the 2w-mod2 and Rss-mod.  At a minimum, I would like to wireless to go into alarm even if it cannot trigger the wired smokes.  Thanks! :pray:
  12. L

    ELK M1 and System Sensor wiring

    Thanks for the information and help.  I assume the EOL resistors that are at the 2W-MOD are 2200, correct?
  13. L

    ELK M1 and System Sensor wiring

    I need some additional assistance on this subject.  I have purchased 10 SS 2WTA-B smokes, the RRS-MOD and 2W-MOD2.  I need clarification on the correct connections to the ELK panel.  I have attached the link to the diagram (Figure 2) that I believe is correct to show a trouble zone.  Can someone...
  14. L

    Burglar Follower

    I was also concerned about that.  Maybe the best option is to put door sensors on the garage doors and program them as entry/exit and the door into the house and interior PIR as follower.
  15. L

    ELK and System Sensor 2WTA-B Smoke

    Thanks for all the help!