Sonos works great and has a plugin for Homeseer that lets you customize anything if you want to tinker. I use mine for whole house announcements from Homeseer.
I have a cable running from the panel to the opener. Connects to the same two wire connections as the wall switch. Setup the Elk for a momentary relay cycle and works great. Also have two zones for door contacts. One when closed and a second when fully opened. Have some events in Homeseer to...
I am doing something similar. I have 4 RIB RIBMN24C connected to thermostat and 24vac transformer to "monitor" the thermostat functions back to my Elk panel. I have a RCS TR-16 connected to the elk but it does not report or you have no way of knowing when the system is running. Just the ordered...
I use the DD-WRT firmware on an Asus router. It has DDNS support for all of the major systems. Using it with No-ip.com right now. I just checked and it supports zoneedit.
See if you router is supported by DD-WRT and update it. Plus you get tons of other options beside just a good DDNS update...
I used old cables/connectors from the HD , power, reset switches from the front panelof a old computer case. Worked good.. You need 2 two pins ones. Uplink 7 & 9 are next to each other and 10 & 8 can be paired. Only Connect the three you need.
I have also had InfiniTV since they first came out. Currently running this on a Window 7 setup. I also have two old Linksys extenders that work Ok but are a bit slow and laggy on the interface. I use them both on wired connections. I only rent one cable cars from the Cable co. I saved some...
Jumpers are the same as 2500. Only three wires (TX, RX, Gnd) are needed from the M1XSP DB9 to the 4500. No flow control line or other connections are needed.
Three rows of data:
1. 44018 or maybe a B
2. Double SS character AG then a diamond symbol
3. W688 or maybe a B
https://dl.dropboxusercontent.com/u/18831497/Q27.JPG
Just did a port scan on the home network and found that my XEP shows three services open. Port 80 and 2601 I recognize and understand but I also show a FTP server on port 21. Tried loggin into it and could not with the regular name/pass. It replied back 220 NET+OS 6.3 FTP server ready.
What is...
All setup as of today. Jamie from Alarm Relay called me and stepped me through the setup. Tested several zones and the Smoke detectors and all is working.
I have installers manual .pdf for the 4500ez if anyone needs it.
I have located a .pdf copy of the 4500ez install manual. Covers everything except the 12 pin header com port. Your help with the serial connection was key. I have the manual if anyone else is considering this setup.
4500ez seems like it is working. All the LEDs are normal and unit reports back...
Who do you have service with? Just received the unit today and plan to install it tomorrow. Just not sure what comes after that.
Would you happen to have the install guide mentioned In the he quick start sheet? Web site Says it is something only available to dealers but hopefully somebody has...
See this post for examples of sending text over the network connection from the Elk.
http://cocoontech.com/forums/topic/24194-how-do-i-send-text-over-tcp-from-elk/