  1. J

    Zwave switches 3way and 4way?

    I dont see any 3way or 4way Zwave switches for sale.  What am I missing?  The room I most want to control has several of each.   Thanks   John  
  2. J

    Honeywell siren won't go off, just chirps once.

    I discovered that I did not have a good connection to the battery.  It was also causing the system to be a little sluggish, or at least looked slow at the keypad display.   Thanks   John
  3. J

    Honeywell siren won't go off, just chirps once.

    I have a Honeywell 20P that I installed and programed myself.  It has 2 expander boards.  It has been working flawlessly for at least a year.  Suddenly the siren will not go off when the alarm is triggered, it just beeps once.  Because of this, the Wireless GSM sender does not send a signal to...
  4. J

    Honeywell Vista 20P 4219 expander board error

    Yes, the boards came with different instructions and labels.  My mistake was assuming the instructions were identical.
  5. J

    Honeywell Vista 20P 4219 expander board error

    We are all right, at least partially.   On the newer looking 4219, dip switch 7 differentiates between normally closed and EOL. On one of mine, position 7 is not used but must be set to on or it will not work. Both of these are green and look identical except the printing and stickers.   Oddly...
  6. J

    Honeywell Vista 20P 4219 expander board error

    I do believe that I miss understood the instructions.  I will turn 7 to off.  Thanks for pointing out my mistake.
  7. J

    Auxiliary Power Supply Mounting Location

    I watched a youtube video "bounder27" I think describing how to install a smaller Altronics  power supply for a Vista Alarm board.  He suggest that it is necessary  for all the 12v power supplies to share a low voltage common for proper voltage.
  8. J

    *** Recomendation for a Shed door contact

    you should be able to use a standard magnetic contact switch.  Since shed doors tend to have some play in them, I would put the switch close to the hinge side so that any incidental movement of the doors will not trigger the alarm.
  9. J

    Honeywell Vista 20P 4219 expander board error

    I have a new 20p with 2 4219 expander boards addressed as 7 (107) and 8 (108)  When I open any connection, the panel displays a check 107 fault with no chime or alarm.  I suspect that the board is bad.   I set the dip switches according to the instructions.  1 and 8 on and 2-7 to "7" for zones...
  10. J

    AD2PI PI to serial adapter Shield

    I am going to install HS2 on a Raspberry PI 2B.  I have read that the AD2USB will work in this configuration.  I found this direct mount shield from the same manufacturer AD2PI.   can the AD2PI work on a Raspberry PI 2B that is running HS3? It seems like a more elegant and reliable solution...
  11. J

    Vista 20P Controlling a detached garage

    I am also looking for a similar solution.   i want to run Homeseer HS3 on a Raspberry PI 2B with a AD2PI   I believe that the software that comes with the AD2USB and AD2Pi  interfaces can control Honeywell relay expansion boards.  Some of these boards are designed to be mounted and independently...
  12. J

    what is the difference between honeywell and Intelisense

    I was looking around for some accessories for my Vista 20P panel and see a lot of Intelisense boards and sensors.  Are they compatible with Vista?   Specifically the S3201.   I am mainly looking for a zone expander at the moment.       Thanks   John
  13. J

    Has anyone used a Denkovi ethernet relay board with homeseer?

    Has anyone used a Denkovi ethernet relay board with homeseer?   http://denkovi.com/ethernet-io-relay-module-snmp-web-12-relays   This looks like a good way to expand a home automation system, especially in a remote location.   Has anyone written a Homeseer plugin for this?   Thanks   John
  14. J

    New to home automation

    I read up on the HomeGenie  The author must be a genius as well as very generous with his talent and time.  I am addicted to my iphone, and Homegenie doesn't seem to have a IOS app yet.   One of the things that is holding me back is that the Homeseer ADIO interface looks like 1980s technology...
  15. J

    68 Camaro starting problem

    You have probably checked all of your ground connections, but you might double check.  Unlike A/C current, D/C current is very sensitive to dirty or corroded connections. just a little rust can create a lot of resistance.     John