    Two relays off one output

    The problem is .... I used output 7 to trigger a 912 relay about 75' away. worked fine for about 6 months. Then the output stayed energized no matter what the rule or the keypad said. The keypad would show the output off, all software would show the output off but it was energized. Wasn't sure...
  2. A

    Two relays off one output

    I ran into a problem which may be my own doing. had a 912 relay about 75 feet from the panel and used an output to trigger it. The wiring is standard alarm wire so I am assuming I had a voltage drop and increase in current.  I am trying not to have to snake new wire so I am thinking of putting a...
  3. A

    ELK M1 outputs always on

    Thanks, That does seem to be a good next step. Will give it a try.
  4. A

    ELK M1 outputs always on

    That's what I was afraid of, but didn't want to think about that.  Was hoping for some simple solution that I was just missing.
  5. A

    ELK M1 outputs always on

    Looking for help on why outputs 7-16 are always on. I do not have an output expander board so have wired relays to 4 of the outputs. The always on is something new and this has not always been the case. I have checked the voltage across output 15 and the neg output and get 13 volts constant. I...
  6. A

    Light switches

    I have a Elk Security system installed along with a ISY994izw. I have installed Trane thermostats onto the ISY and they are functioning fine. It's time to install light switches and would like recommendations on z-wave vs Insteon. I have the PLM as it came with the ISY.   Looking for any input...
  7. A

    ELK-M1XRFEG

    VC1234 That's the conclusion we came to. The GE wireless sensors take up to the 68 minutes to get them all to respond. If I check "Jam Detection" the keypad shows the zones as violated until they respond and can not arm the house until they all respond.  If I uncheck "Jam Detection" all zones...
  8. A

    ELK-M1XRFEG

    DEL When I did the walk through test I got most 7.  I believe 8 is the strongest.   Mike The requirement for the open and close is a setting in the Globals G29-G42 "UL Wireless Jam Detect" My problem is I can be away for weeks at a time. If I lose power for an extended period past what the...
  9. A

    ELK-M1XRFEG

    I installed an new M1 panel along with 8 wired sensors and 42 wireless sensors (interlogix 319.5 ) most of the sensors are the new Tx-E201 window/door sensors. When I reboot the panel it takes about an hour to go through all the zones. It keeps showing that # zones are violated.  After about an...
  10. A

    60-807-01-95R compatible with elk-M1XRFEG

    Solved!  The problem was that I set up 3 wireless groups at one time starting with group 3. I entered the basic name and info on all zones but had only set up wireless devices on about have of the zones in group 3. Had the group 4 zones disabled and started with the wireless motion sensors on...
  11. A

    60-807-01-95R compatible with elk-M1XRFEG

    Hi am trying to install the interlogix wireless motion sensors # 60-807-01-95R .   I entered the TX number using the RP2 program. Settings 1=Supervision, no options selected, PIR selected, Keyfob ID 199 H ID 5098116, Loop 0.   I already installed the interlogix wireless window and door sensors...
  12. A

    Elk M1XRFTWM

    Thanks that what I thought.   Thanks for confirming
  13. A

    Elk M1XRFTWM

    Does anyone know if the Elk two way transceiver is backwards compatible with ge wireless sensors? I have many of the "ge interlogix tx-1012-1-1" receivers and need to know that the new Elk Transceiver will work with them.   Thanks!
  14. A

    Help selecting Lighting controller w/ Elk M1

    I have installed the Elk M1 panel and have had it up and running for about 6 months with no problems. It controls all security (wired and wireless sensors) and smoke detectors, along with three Aprilaire thermostats. It is time to add lighting controls. The house is approximately 4000 sq. ft...
  15. A

    DSC 832

    Is there any way to undo the monitoring without the installer code? I am guessing I can always default the system and start over with all programing.